AD600

Plug-in module DD600
  • Helps reduce installation time
  • Up to 32 addresses can be set
  • Fits into motion sensor connector block
  • Supported by ATS1290N DGP
View all

At a glance

The AD600 IADS module is supported by the ATS1290N DGP, and designed to be installed directly on the terminal block of the DD600 series (standard as well as AM variants).

A 3 core connection only is required to the ATS1290N DGP / ATS Master panel.

As the AD600 acts as I/O interfaces with one dual-zone input and two outputs, it is necessary to program anti-masking detectors to signal a technical fault or
antimasking condition to the alarm output.

Details

  • Helps reduce installation time
  • Up to 32 addresses can be set
  • Fits into motion sensor connector block
  • Supported by ATS1290N DGP

Technical specifications

General
Accessory group
Motion sensors
Type
Module
Address range 0 to 31
Device type / Category T3 / PIR
Electrical
Operating voltage
9 to 24 VDC
Current consumption
200 mA (Max. capacity output day/night)
200 mA (Max. capacity output walk test)
900 µA (Max. @ 13.4 VDC)
400 µA (Min. | 13.4 VDC)
Approx. 75 µA (Out of bus)
IADS-bus voltage 12 or 24 VDC